Plastic Blood Gas Capillaries

Plastic Blood Gas Capillaries

In vitro diagnostic medical device for capillary

blood collection for pH/blood gas, oximetry,

electrolyte and metabolite analysis.

SC’s plastic blood gas capillaries feature even coating with balanced heparin and

an optimized blood flow. The special treatment of the plastic blood gas capillaries

with anticoagulant provides the basis for prevention of blood clotting during blood

collection. This facilitates the diagnostic process on modern analysers.

The risk of injury and infection for all participants during the blood collection process

is minimized thanks to the unbreakable and flexible construction of the plastic blood

gas capillaries.

The SC plastic blood gas capillaries are made of chemically neutral plastic with minimal

gas-permeability. For all intended uses in which glass capillaries would be a safety risk,

plastic blood gas capillaries are the optimum solution.

The plastic blood gas capillaries are heparinised as standard with ~50 I.U./ml  or ~100 I.U./ml.

Other heparin concentrations are available on request.

The practicality of the hygienic round plastic dispenser box has stood the test of time and is the

established type of packaging. Each dispenser contains 100 plastic blood gas capillaries. The

capillaries can easily be extracted using the practical capillary holder which helps avoid direct contact.

As an alternative to the round plastic dispenser box SC plastic blood gas capillaries are now also available in a large-volume, environmentally friendly cardboard tube box. The re-

box contains 250 capillaries, thus minimising storage space and handling effort at the point of care.

SC Sanguis is specialised in developing individual, customised options for sample volume, labelling and anticoagulant coating for plastic capillaries. Custom-made production is our profession.

Capillary-volume Heparin-concentration Length Outerø Packaging
pcs.
packed
in*
REF
~90 μl ~50 I.U. ~80 mm ~1,75 mm 10 x 100 SD 101080
~100 μl ~50 I.U. ~90 mm ~1,75 mm 10 x 100 SD 101090
~110 μl ~50 I.U. ~100 mm ~1,75 mm 10 x 100 SD 101100
~130 μl ~50 I.U. ~120 mm ~1,75 mm 10 x 100 SD 101120
~165 μl ~50 I.U. ~150 mm ~1,75 mm 4 x 250 SD 101150
~200 μl ~50 I.U. ~180 mm ~1,75 mm 4 x 250 SD 101180
~140 μl ~50 I.U. ~90 mm ~2,35 mm 10 x 100 SD 102090
~155 μl ~50 I.U. ~100 mm ~2,35 mm 10 x 100 SD 102100
~185 μl ~50 I.U. ~120 mm ~2,35 mm 10 x 100 SD 102120
~100 μl ~100 I.U. ~90 mm ~1,75 mm 10 x 100 SD 101091
~110 μl ~100 I.U. ~100 mm ~1,75 mm 10 x 100 SD 101104
~130 μl ~100 I.U. ~120 mm ~1,75 mm 10 x 100 SD 101122
~80 μl ~100 I.U. ~54 mm ~1,90 mm 10 x 100 SD 102118
~115 μl ~100 I.U. ~78 mm ~1,90 mm 10 x 100 SD 102117
~150 μl ~100 I.U. ~100 mm ~1,90 mm 10 x 100 SD 102116
~170 μl ~100 I.U. ~100 mm ~2,00 mm 10 x 100 SD 105107
Analyser Type Manufacturer Recommended Blod Gas Capillaries
from SC – Sanguis Counting
GEM4000 IL 102116 102117 102118 105107
ABL7 Radiometer 101122 101122
8 XX Radiometer 101122 101122
9x Serie Radiometer 101122 101122
8x Serie Bayer / Siemens 102120
12xx Serie Bayer / Siemens 102120
B21 Roche COBAS 101180