Mission® U 120

About Mission® U120 Urine Analyzer

The Mission® U120 Urine Analyzer is a great tool to use with the Mission Urinalysis Reagent Strips. This analyzer has the capability of running up to 120 tests per hour and saving and recalling 2000 results automatically. The Mission® U120 Urine Analyzer facilitates high volume testing and provides a sense of confidence in the accuracy of the results. This analyzer is 510(k) Cleared and CLIA Waived for use with the Mission® Urinalysis Reagent Strips and Mission® Urine Controls.

Product Specs

FeaturesSpecifications
TypeManual
MethodologyReflectance Photometry
DetectionPhotosensitive Diode
ThroughputSingle Test Option: 60 tests/hour
Continuous Test Option: 120 tests/hour
Test CategoriesRoutine, STAT and QC
MemoryLast 2,000 results
Strip Incubation Time1 Minute
Wavelength of Monochromatic LED525 nm and 635 nm
Default Strips8, 9, 10, 11 Parameters (108 mm x 5 mm)
Strips Available1-14 parameters (108 mm x 5 mm); see URS Parameters
Total Combinations Per Analyzer4 Combinations
Analyzer PortsRS232C Port for Barcode Reader or Data Transfer
USB Port for Data Transfer
25 Pin Parallel Port for External Printer
Data Entry CapabilitiesOperator/Patient ID – Manual Entry and Barcode Reader (Up to 20 characters)
Connection CapabilitiesInternal Thermal Printer (included)
Optional External Printer (not included) RS232C Barcode Reader (optional)
USB or RS232C Data Transfer Cable (optional)
Major Readable BarcodesCode 128, Code 39, Codabar (NW-7), EAN 8, EAN 13, Interleave 25 , UPCA, UPCE
CalibrationAutomatic
Available Languages on the ScreenEnglish and additional language(s)
Operating Conditions0-40°C (32-104° F); < 85% RH
Storage Conditions -5-50°C (23-122° F); < 90% RH
Power Source100-240 VAC, 50-60 Hz
Dimensions (L x W x H)27.2 cm x 26.9 cm x 14.6 cm (10.7″ x 10.6″ x 5.7″ )
Display Dimensions (L x W)10.8 cm x 5.7 cm (4.2″ x 2.2″)
Weight2.6 kg (5.7 lbs) without batteries or power supply

Product Accessories

Barcode Reader
Optional Bar-code Reader connects to the analyzer for faster input of information. It scans the canister code for quick canister code recognition to operate the analyzer as well as quick entry of Patient ID. Both canister code and Patient ID can be entered manually as well.

Printer Paper Rolls
Printer paper rolls is available in both Thermal paper and Sticker paper. Printing results may either be automatic or manual. Can print up to 3 copies per test results for convenient record management.

Data Transfer
Data Transfer Kit is used for data transfer to Personal Computer (PC) or Laboratory Information System (LIS). RS232 cable is required for connection to a personal computer and the analyzer in order to download data to PC or LIS.